PROFINET Module Reference Table

Module ID Byte Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0

Acquisition Control

0x101

0

 

 

 

Trigger

 

 

Acquisition Status

0x201

0

Online

 

Acquisition Error

 

Trigger Acknowledge

Trigger Ready

1  
2..3 Acquisition ID
 

Inspection Control

0x102

0

Clear Error

 

Execute Command

 

Inspection Results Acknowledge

 

 

Inspection Status

0x203

0

Error

 

Inspection Passed

1   Command Failed Command Completed Command Executing Results Valid   Inspection Completed  
2..3

Error ID

 
Command Control Input

0x108

0..1

Command ID (16-bit)

 

Command Control Output

0x108

0..1

Current Program ID (16-bit)

2..3

 

 

Inspection Results

0x401 (16)

0x402 (32)

0x403 (64)

0x404 (128)

0x405 (250)

0..1

Inspection ID

2..3

 

4..253 max

Inspection Results

Note: For more information about Inspection Results, see Inspection Results.