PROFINET Module Reference Table
| Module | ID | Byte | Bit 7 | Bit 6 | Bit 5 | Bit 4 | Bit 3 | Bit 2 | Bit 1 | Bit 0 |
|---|---|---|---|---|---|---|---|---|---|---|
|
Acquisition Control |
0x101 |
0 |
|
|
|
Trigger |
|
|||
|
Acquisition Status |
0x201 |
0 |
Online |
|
Acquisition Error |
|
Trigger Acknowledge |
Trigger Ready |
||
| 1 | ||||||||||
| 2..3 | Acquisition ID | |||||||||
|
Inspection Control |
0x102 |
0 |
Clear Error |
|
Execute Command |
|
Inspection Results Acknowledge |
|
||
|
Inspection Status |
0x203 |
0 |
Error |
|
Inspection Passed |
|||||
| 1 | Command Failed | Command Completed | Command Executing | Results Valid | Inspection Completed | |||||
| 2..3 |
Error ID |
|||||||||
| Command Control Input |
0x108 |
0..1 |
Command ID (16-bit) |
|||||||
|
Command Control Output |
0x108 |
0..1 |
Current Program ID (16-bit) |
|||||||
|
2..3 |
|
|||||||||
|
Inspection Results |
0x401 (16) 0x402 (32) 0x403 (64) 0x404 (128) 0x405 (250) |
0..1 |
Inspection ID |
|||||||
|
2..3 |
|
|||||||||
|
4..253 max |
Inspection Results |
|||||||||