Installing a Lens with High Power Illumination Accessory (HPIA)
For a list of lenses compatible with the HPIA, see the DataMan 370 Series Reference Manual and the DataMan 470 Series Reference Manual, respectively.
Tools needed:
- Wrench for lens locking ring (10.3 mm LL only - delivered by Cognex with Liquid Lens module)
- Phillips screwdriver (PH0)
- Phillips screwdriver (PH1)
To install a lens module of a DataMan 370 or 470 reader with HPIA, perform the following steps:
-
To install the lens, see:
-
Place the HPIA on the front of the reader.
-
Insert the lens cover mounting plate into the HPIA and secure them to the reader using the four M3 screws.
M3 x 16 mm screws
Note: Use a 3 mm hex wrench to torque the screws to 0.34 Nm (3 in-lb). Tighten in sequence.
-
Attach the C-mount lens cover to the front of the plate and secure it using the four M2 screws.
Note: For lenses that do not fit under the DM500-CMTLC-000 lens cover, you are required to use the DM500-LNSEXT-000 lens cover extension.M2 x 5 mm screws
Note: Use a Phillips Screwdriver (PH0) to torque the screws to 0.09 Nm (0.8 in-lb). Tighten in sequence.