Two-dimensional matrix symbols include data fields of modules
nominally lying in a regular polygonal grid, and any reference decode
algorithm must adaptively map the center positions of those modules to
extract the data. Axial Nonuniformity tests for uneven scaling of the
symbol which would hinder readability at some non-normal viewing
angles more than at others.
Namespace: Cognex.VisionPro.IDThis is a measure of how much the sampling point spacing differs between the X and Y axes.A value of 0 means there is no difference.
Assembly: Cognex.VisionPro.ID (in Cognex.VisionPro.ID.dll) Version: 75.0.0.0
Syntax
Property Value
Type: DoubleSee Also