CogPrio SetOutput Method Cognex VisionPro 9.8
Set an output line.

Namespace: Cognex.VisionPro.Comm
Assembly: Cognex.VisionPro.Comm (in Cognex.VisionPro.Comm.dll) Version: 75.1.0.0
Syntax

public void SetOutput(
	CogPrioBankConstants outputBank,
	int outputLineNumber,
	CogPrioOutputLineValueConstants valueToSet
)
Exceptions

ExceptionCondition
CogPrioInvalidBankException Thrown if outputBank is set to an invalid bank.
CogPrioInvalidLineException Thrown if outputLineNumber is set to an invalid line.
Remarks

Hardware platforms and supported I/O lines:

Cognex Communication Card 24C
InputBank0, Line0-Line78 general purpose inputs numbered 0-7
OutputBank0, Line0-Line1516 general purpose outputs numbered 0-15

Cognex Communication Card 24A (Cognex Vision Controller)
InputBank0, Line0-Line78 general purpose inputs numbered 0-7
OutputBank0, Line0-Line1516 general purpose outputs numbered 0-15
DS1000OutputBank0, Line0Camera 0 Enable (Not For Application Use)
DS1000OutputBank0, Line1Camera 1 Enable (Not For Application Use)
DS1000OutputBank0, Line2Camera 0 Trigger
DS1000OutputBank0, Line3Camera 1 Trigger
DS1000OutputBank0, Line4Camera 0 Control (Not For Application Use)
DS1000OutputBank0, Line5Camera 1 Control (Not For Application Use)
DS1000OutputBank0, Line6Camera 0 Power (Not For Application Use)
DS1000OutputBank0, Line7Camera 1 Power (Not For Application Use)