CogImageSharpnessTool Run Method Cognex VisionPro 9.7
Runs the tool using the current parameter settings.

Namespace: Cognex.VisionPro.ImageProcessing
Assembly: Cognex.VisionPro.ImageProcessing (in Cognex.VisionPro.ImageProcessing.dll) Version: 73.0.0.0
Syntax

public override void Run()

Implements

ICogTool Run 
Events

Event TypeReason
ICogTool Running

Fires before the tool runs.

ICogChangedEvent Changed

Fires when the tool runs. If the run was successful, results are generated; if the run was not successful, no results are generated and the previous results are cleared. Use RunStatus after CogImageSharpnessTool returns or in a Ran event handler to determine whether a run was successful or unsuccessful.

The following state flags may be affected:

    ICogTool Ran

    Fires after the tool runs.

    Remarks

    Runs the tool. The computed sharpness score is placed in the Score property.

    If Mode is GradientEnergy, the image is processed using Gaussian smoothing before measuring sharpness.

    See Also