The classifier tool identifies the category of a part shown in an image.
Cognex.Vision ShareableBase
Cognex.Vision ChangedEventShareableBase
Cognex.Vision.Implementation TrackedItemBase
Cognex.Vision.Implementation ToolBase
Cognex.Vision.ViDiEL ClassifyTool
Namespace: Cognex.Vision.ViDiEL
Assembly: Cognex.Vision.ViDiELClassify.Net (in Cognex.Vision.ViDiELClassify.Net.dll) Version: 9.10.0.0
The ClassifyTool type exposes the following members.
| Name | Description | |
|---|---|---|
| ClassifyTool | Constructs a default ClassifyTool object. This new tool contains a default set of run params. |
| Name | Description | |
|---|---|---|
| CheckRunConditionsSelf | Performs RunCondition check by the tool itself. | |
| CopyBase | Create a copy of this tool. | |
| CreateCurrentRecord | Creates a new set of records that represents the tool's current state. | |
| CreateLastRunRecord | Creates a new set of records that represents the tool's last-run state. | |
| Equals | Compares the equality of this object with another. (Overrides ToolBase Equals(Object).) | |
| GeneratePredictedResults | Internal Cognex use only. | |
| GetContainerAsILinkManager | Get the container which contains the Tool. | |
| GetHashCode | Returns the hash code of this object. (Overrides ToolBase GetHashCode .) | |
| GetType | Gets the Type of the current instance. (Inherited from Object.) | |
| GetTypeMeta | Get the TypeMeta that describes the type of this object. | |
| IsCheckRunConditionsDelegateToOwner | Check if tool checks its RunCondition by its owner. | |
| ResumeAndRaiseChangedEvent | Re-enables raising of the ChangedEvent after SuspendChangedEvent has been called, and raises the ChangedEvent if the ChangedEventSuspended count is reduced to zero and any changes were made while events were suspended. Must be called once for each call to SuspendChangedEvent. | |
| Run | Runs the tool. This method is guaranteed to not throw an exception. Any exception generated in the course of running the tool will be caught and a string representation of that exception will be packaged in the Message property of the tool's RunStatus. Should this occur, the Result property of the tool's RunStatus will be set to Error. It is the user's responsibility to examine the tool's RunStatus after calling Run. | |
| SuspendChangedEvent | Temporarily suspends the raising of the ChangedEvent. May be called more than once, and a corresponding call to ResumeAndRaiseChangedEvent must be made for each call to SuspendChangedEvent. | |
| ToString | Returns a human readable string that represents the object. |
| Name | Description | |
|---|---|---|
| Equality | Compares the equality of two ClassifyTool objects. | |
| Inequality | Compares the inequality of two ClassifyTool objects. |
| Name | Description | |
|---|---|---|
| SfAutoGrabCount | ||
| SfCurrentRecordEnable | ||
| SfInputImage | ||
| SfLastRunRecordDiagEnable | ||
| SfLastRunRecordEnable | ||
| SfPattern | ||
| SfResult |
| Name | Description | |
|---|---|---|
| AutoGrabCount | Get Gets the value of the AutoGrabCount. This value controls how many images can be auto grabbed in the ViDiELClassify Edit Control. | |
| ChangedEventSuspended | Indicates if raising the ChangedEvent has been suspended. | |
| CurrentRecordEnable | Get Enable creation of records by bitwise ORing the appropriate CurrentRecordConstants. | |
| Enabled | Whether the tool is enabled to run. If false, calling the tool's Run function will not actually run the tool and will cause no change in the tool's state. | |
| FailOnInvalidDataBinding | Whether the tool's Run method is to fail if executed while one or more DataBindings (aka Links) are Invalid. | |
| Handle | (Overrides ToolBase Handle.) | |
| ID | Gets the ID of the tracked item. | |
| InputImage | Get Gets input image that will be used at run time. | |
| Inputs | A collection of named Input Pin values. | |
| LastRunRecordDiagEnable | Get Enable creation of diagnostic subrecords by bitwise ORing the appropriate ClassifyLastRunRecordDiagConstants. | |
| LastRunRecordEnable | Get Enable creation of records by bitwise ORing the appropriate ClassifyLastRunRecordConstants. | |
| Name | Get the name of the tracked item. | |
| Outputs | A collection of named Output Pin values. | |
| Parent | Return a reference to the containing tracking collection. May be null. | |
| Pattern | Get Gets the pattern for this Classify tool. | |
| Result | Gets the result. | |
| RunStatus | Gets general information about the last call to the tool's Run method. Note that serious errors that occur within the tool's Run method may only be detected by examining the RunStatus after calling Run. It is the user's responsibility to examine the tool's RunStatus after calling Run. |
| Name | Description | |
|---|---|---|
| Changed | The actual event. | |
| NameChanging | This event is raised when the Name is about to change. Note that this is a cancellable event. | |
| Ran | Event that is raised at the end of the tool's Run method. | |
| Running | Event that is raised at the start of the tool's Run method. |