GetDeEnergizeOutputs
Returns the De-Energize Outputs While Offline setting configured in the Discrete I/O Settings dialog. For more information, see Configure Discrete I/O Lines.
GetDeEnergizeOutputs Inputs
Syntax: EV GetDeEnergizeOutputs()
GetDeEnergizeOutputs Outputs
Returns a status code, followed by the number of characters (in bytes) for the results, then the results in XML format. The status codes are:
| Status Codes | Description |
|---|---|
| 1 | The command was executed successfully. |
| 0 | Unrecognized command. |
| -2 | The command could not be executed. |
| -6 | User does not have Full
Access to execute the command. |
GetDeEnergizeOutputs Example
To retrieve the De-Energize Outputs While Offline setting, issue the following command: EV GetDeEnergizeOutputs()
The In-Sight sensor responds with a status code (1), followed by the number of characters, in bytes (18). Finally, the De-Energize Outputs While Offline setting is returned.