In-Sight® Explorer 6.2.1 Release Notes

© Copyright 1999-2021 Cognex Corporation. All rights reserved.

Revision: 6.2.1.27, 2021 October 04

Overview

This document describes the In‑Sight Explorer software, including the following topics:

Note: For the latest release notes and documentation, visit: support.cognex.com/documentation/in-sight.

System Requirements

This section describes system requirements for In‑Sight Explorer software.

PC Hardware Minimum and Recommended Requirements

Notes:

Minimum Recommended
Intel® Celeron® 1000M processor running at 1.8GHz (or equivalent) Intel Core™ i7 processor running at 2.7GHz (or equivalent)
2GB of available RAM 4GB of available RAM
4GB of available disk space 8GB of available disk space
Video card that can display 1024 x 768 resolution at 24-bit color depth (the DPI Display setting must be set to 96 DPI) Video card that can display 1920 x 1080 resolution at 32-bit color depth (the DPI Display setting must be set to 96 DPI)
Network interface card (at least 100Mbps) for connecting to an In-Sight vision system Gigabit network interface card for connecting to multiple In-Sight vision systems

Operating System Requirements

In-Sight software has been tested on the following operating systems:

Although you can install and run In‑Sight Explorer on other Windows operating systems, PCs that do not meet the preceding requirements are not officially supported.

Supported Languages

Firmware Version Support

In-Sight 6.2.1 software contains three firmware versions:

In-Sight vision systems that have older firmware versions might work properly. However, some features are unsupported with older firmware versions and are not fully tested. For optimal performance, update vision systems that run older firmware to the most recent, supported firmware versions. For a list of models and supported firmware versions, see the Firmware Versions topic in the In-Sight® Explorer Help file.

In-Sight Firmware 6.2.1

In-Sight Firmware 5.9.2

In-Sight Firmware 4.10.5 PR1

Microsoft .NET Framework 4.5.2

In-Sight software requires Microsoft .NET Framework 4.5.2. If the In-Sight software installer fails to detect Microsoft .NET Framework 4.5.2, it attempts to download and install it.

New Features

 

Introducing Cognex Network Server 3.0.0, a desktop and web application that supports single-sign-on, built-in audit message server, managing users across all devices, and creating and managing trusted certificates required to establish an HTTPS connection between In-Sight devices and the Web HMI.

Introducing Compare Jobs, allowing you to see a list of cell differences between two .job files. Accessible from the System menu and file pane of the In-Sight Explorer, and through and API & sample project in the ISDK..

New Job Timeout spreadsheet functions allow for advanced-level control of the job’s execution duration.

Changes & Fixes

Notes:

Issue# Change/Fix Applicable Firmware Version

IS‑5418

Fixed issue where the PLC Time Synchronization details screen was not working correctly for certain In-Sight Explorer languages.

6.2.1

IS‑5403

Fixed inability of In-Sight to maintain or recover an FTP connection if a separate FTP operation is performed. This can impact or be caused by WriteImageFTP, WriteFTP, Import/ExportData, or file operations. Affects 6.1.1 - 6.1.3 firmware on all models.

6.2.1

IS‑5368

Improved OCRMax read scoring for dash and other small punctuation characters.

6.2.1

IS‑5365

Fixed rare combinations of exposure duration and image row settings that corrupted the acquired image. Affected AdvantageEngine and In-Sight 200X models only.

6.2.1

IS‑5337

Fixed 'CjsDialogView' error that prevented use of secure Web HMI in certain cases.

6.2.1

IS‑5202

Improved speed of the ExtractHistogram when using a small input region.

6.2.1

IS‑5201

Fixed an issue where the first FTP transfer attempt by the camera failed after bringing the camera online. Affects only v6.1.1 - v6.1.3 firmware.

6.2.1

IS‑5166

Fixed issue where not all DLL signatures appeared in the SDK.

6.2.1

IS‑5096

Reverted changes to audited values will now cause audit messages to be sent after canceling a dialog.

6.2.1

IS‑5040

Fixed issue where Operator (protected) level users were not able to modify settings of EasyBuilder tools.

6.2.1

IS‑4947

Fixed issue when on job load, Color Pixel Count tool could cause Communications device to disappear, if the tool was dependent on comms input.

6.2.1

IS‑4842

Fixed an issue where set PortNum did not work correctly. Affects v6.1.0 - 6.1.3 firmware

6.2.1

IS-4785 Fixed a slowdown in the ReadIDMax function in cases where the code orientation was rotated 90 degrees relative to the orientation of the search region.

6.2.1

IS-4785 The max search ROI of the ReadIDMax function is extended to 2592 x 2592 for code types that previously supported a max region size of 2592 x 2048. 6.2.1

IS‑4455

Fixed error in the Web HMI occurring when you modify the camera's acquisition start row and the number of rows.

6.2.1

IS-383 Previously, there was an issue with UDP connection: sometimes the UDP WriteDevice did not reestablish connection after a disconnect. 6.2.1

Known Issues

Note: The release notes include issue numbers (where applicable) to better track known issues reported by Cognex Technical Support.
Issue# Issue Affected Firmware Version

IS‑5258

Web HMI: 403 error seen in browser after successfully firmware updating certain IS2000 devices.

Workaround: performing a 2nd firmware upgrade.

6.2.1

IS‑4432 If the ReadIDMax function is configured to read Data Matrix symbols, the Enable Training option is checked, and Train Perspective is selected from the Perspective drop-down, subsequent attempts to read the symbol will fail. 6.2.1
IS‑2854

After a power-cycle, if the vision system/sensor receives a new trigger, no new results are added to the Sensor Filmstrip queue. However, the image and spreadsheet continue to update correctly.

 

Conditions:

  • An In-Sight vision system/sensor is configured to use the Sensor Filmstrip.
  • In the Sensor Filmstrip Settings dialog, the Queue drop-down is configured as Separate Pass and Fail Results.
  • In the Sensor Filmstrip Settings dialog, the Queue Size is increased or decreased.
  • The vision system/sensor is power-cycled.
  • After the power-cycle, the vision system receives a new trigger.

Workaround:

  1. Within In-Sight Explorer, click Sensor menu > Sensor Filmstrip Settings to launch the Sensor Filmstrip Settings dialog.
  2. From the Queue drop-down, select an option other than Separate Pass and Fail Results and click OK.
  3. Relaunch the Sensor Filmstrip Settings dialog.
  4. From the Queue drop-down, select Separate Pass and Fail Results and click OK. When the vision system/sensor is triggered, results are correctly added to the queue.
6.2.1
FFP‑1646 In-Sight 2000 series vision sensors running In-Sight firmware version 5.9.1 and later are not certified for PROFINET Conformance. To run In-Sight 2000 series vision sensors with PROFINET Conformance, you can downgrade the In-Sight 2000 series vision sensors' firmware version to In-Sight 5.9.0 or 5.8.x. 5.9.1 & 6.2.1

IS‑2195

If In-Sight Explorer is installed to a PC with a Microsoft Windows 10 operating system and the Beta: Use Unicode UTF-8 for worldwide language support is checked in the Region dialog, the vision system or emulator may not be able to connect to the In-Sight Explorer Spreadsheet View.

 

Workaround: Uncheck the Beta: Use Unicode UTF-8 for worldwide language support checkbox.

  1. In the search box on the Windows taskbar, type Control Pane and select the Control Panel App.
  2. From the Windows Control Panel search box, type Region and select the Region text.
  3. In the Region dialog that opens, click the Administration tab and click the Change system locale... button.
  4. In the Region Settings dialog that opens, uncheck Beta: Use Unicode UTF-8 for worldwide language support and click OK to close the Region Settings dialog.
  5. Click OK to close the Region dialog.
  6. Reboot the PC.
N/A
FFP‑1053

When the vision system is configured to load a job at startup (Sensor menu > Startup) and the EV SetSystemConfig OPCUA.TimeSync Extended Native Mode command is issued, OPC UA Job Tags are missing in the OPC UA client when browsing the address space (Objects > Server > VisionSystem > Results > JobTags node).

 

6.2.1
FFP‑875 Sending the communication settings, such as the IP address, from Mitsubishi iQ Sensor Solution (GX Works) to the In-Sight vision system/sensor is not supported. 6.2.1
IS‑334

When you try to connect your vision system/sensor to the Web HMI for the first time, you may receive a permission error and connection is denied.