Revision: 6.1.0.3, 2020 October 20
This document describes the In‑Sight Explorer software, including the following topics:
This section describes system requirements for In‑Sight Explorer software.
Notes:
| Minimum | Recommended |
|---|---|
| Intel® Celeron® 1000M processor running at 1.8GHz (or equivalent) | Intel Core™ i7 processor running at 2.7GHz (or equivalent) |
| 2GB of available RAM | 4GB of available RAM |
| 4GB of available disk space | 8GB of available disk space |
| Video card that can display 1024 x 768 resolution at 24-bit color depth (the DPI Display setting must be set to 96 DPI) | Video card that can display 1920 x 1080 resolution at 32-bit color depth (the DPI Display setting must be set to 96 DPI) |
| Network interface card (at least 100Mbps) for connecting to an In-Sight vision system | Gigabit network interface card for connecting to multiple In-Sight vision systems |
In-Sight software has been tested on the following operating systems:
Although you can install and run In‑Sight Explorer on other Windows operating systems, PCs that do not meet the preceding requirements are not officially supported.
In-Sight 6.1.0 software contains three firmware versions:
In-Sight vision systems that have older firmware versions might work properly. However, some features are unsupported with older firmware versions and are not fully tested. For optimal performance, update vision systems that run older firmware to the most recent, supported firmware versions. For a list of models and supported firmware versions, see the Firmware Versions topic in the In-Sight® Explorer Help file.
In-Sight software requires Microsoft .NET Framework 4.5.2. If the In-Sight software installer fails to detect Microsoft .NET Framework 4.5.2, it attempts to download and install it.
| New Features |
|---|
| The EasyBuilder 1D and 2D Identification tools and ReadIDMax spreadsheet function's Advanced Decode Mode have been optimized to use Hotbars®, a best-in-class technology that locates, extracts, and decodes 1D barcodes quickly and accurately. The functionality has also been extended to ensure fast and reliable decoding of even the most challenging 2D DPM codes. |
|
The following updates were made to the ReadIDMax spreadsheet function:
|
|
The following updates were made to the 1D tab of the Read 1D Code and Read 1D Codes (1 - 20) Identification tools in EasyBuilder:
|
|
The following updates were made to the Settings tab of the Read 2D Code and Read 2D Codes (1 - 20) Identification tools in EasyBuilder:
|
| Enhanced PDF417 decoder robustness on defects and damage. |
| This release includes QR Code reading enhancements. |
| In-Sight firmware version 6.1.0 and later is current with GS1 General Specifications, Version 19.1. |
|
The following new features were implemented to support the Sensor filmstrip:
|
| A new GetPostInspectionTime Vision Data Access spreadsheet function has been added to return the post-inspection time, in milliseconds, for the previous inspection. This function returns #ERR for the first inspection and if the vision system is Offline. |
Notes:
| Issue# | Change/Fix | Applicable Firmware Version |
|---|---|---|
| IS-4366 |
The GetAllTime Vision Data Access spreadsheet function has been updated to include the pre-inspection time before the job executes, to more accurately report the time for the image to be acquired and the job to execute. Note: The real-world job execution time will not be increased. This change only affects the execution time returned by the GetAllTime function.
|
6.1.0 |
| IS-4313 | When communicating over TCP/IP or UDP, the QueryDevice spreadsheet function now correctly updates to display the data read back from the TCP/IP or UDP device. Previously, the QueryDevice function only updated if it contained an invalid input parameter and returned #ERR. | 6.1.0 |
| IS-4283 | The status bar in the Spreadsheet View and the Results tab in the EasyBuilder View Palette have been updated to display the job execution time and total execution time. The total execution time is the job execution plus any additional pre-inspection and post-inspection time. | 6.1.0 |
| IS-4283 | When the Acquire button is pressed in the Spreadsheet View Profile Job dialog, the Total time correctly displays the job execution time. | 6.1.0 |
| IS-4195 | When using the BeadFind and BeadInspect spreadsheet functions, the bead path no longer always must intersect the bead to correctly find the bead. During inspection, the bead may move, and both edges of the bead may be positioned on one side of the bead path. Previously, the bead would not have been detected and a “No Bead Found” error was reported. | 6.1.0 |
| IS-4119 | When connected to the vision system over FTP and issuing the FTP mget command, files are properly downloaded from the vision system and saved to the default directory of the FTP client on the remote host. Previously, if the vision system was running In-Sight firmware version 5.8.0 - 5.9.2 and the FTP mget command was issued, an FTP 550 error was returned, indicating the file was not found. | 6.1.0 |
| IS-4044 | When the VerifyIDCode spreadsheet function is configured to use ISO 15415:2004 or AIM-DPM - Process Control Metrics, the GetFixedPatternDamage Vision Data Access function now returns a consistent grade for the decoded symbol. | 6.1.0 |
| IS-2965 |
The maximum region size for the following 1D and 2D symbologies has been increased to 2592 x 2048 (Wide x High) for the following symbologies. Previously, the maximum region size for these symbologies was 2048 x 2048.
|
6.1.0 |
| N/A | The 5705 and 5705C vision systems are not supported with In-Sight firmware version 6.1.0. | 6.1.0 |
| N/A | Microsoft Windows 7 Professional, Service Pack 1 (64-bit) is no longer supported with In-Sight software. | N/A |
| N/A | Microsoft .NET Framework 3.5 SP1 is no longer supported with In-Sight software. | N/A |
| N/A |
The OPC Classic Server software is no longer supported. If OPC support is required, it is recommended that you migrate from the OPC Classic Server to the In-Sight OPC UA Server. For more information, see the In-Sight Explorer Help. |
6.1.0 |
| Issue# | Issue | Affected Firmware Version |
|---|---|---|
| IS-4432 | If the ReadIDMax function is configured to read Data Matrix symbols, the Enable Training option is checked and Train Perspective is selected from the Perspective drop-down, subsequent attempts to read the symbol will fail. | 6.1.0 |
| IS-2854 |
After a power-cycle, if the vision system/sensor receives a new trigger, no new results are added to the Sensor Filmstrip queue. However, the image and spreadsheet continue to update correctly.
Conditions:
Workaround:
|
6.1.0 |
| FFP-1646 | In-Sight 2000 series vision sensors running In-Sight firmware version 5.9.1 and later are not certified for PROFINET Conformance. To run In-Sight 2000 series vision sensors with PROFINET Conformance, you can downgrade the In-Sight 2000 series vision sensors' firmware version to In-Sight 5.9.0 or 5.8.x. | 5.9.1 & 6.1.0 |
|
IS-2195 |
If In-Sight Explorer is installed to a PC with a Microsoft Windows 10 operating system and the Beta: Use Unicode UTF-8 for worldwide language support is checked in the Region dialog, the vision system or emulator may not be able to connect to the In-Sight Explorer Spreadsheet View.
Workaround: Uncheck the Beta: Use Unicode UTF-8 for worldwide language support checkbox.
|
N/A |
| FFP‑1053 |
When the vision system is configured to load a job at startup (Sensor menu > Startup) and the EV SetSystemConfig OPCUA.TimeSync Extended Native Mode command is issued, OPC UA Job Tags are missing in the OPC UA client when browsing the address space (Objects > Server > VisionSystem > Results > JobTags node).
Workaround: Use the LoadJob method to reload the job file to the vision system/sensor. For more information, see the In-Sight® Explorer Help file. |
6.1.0 |
| FFP-875 | Sending the communication settings, such as the IP address, from Mitsubishi iQ Sensor Solution (GX Works) to the In-Sight vision system/sensor is not supported. | 6.1.0 |
| IS-334 |
When you try to connect your vision system/sensor to the Web HMI for the first time, you may receive a permission error and connection is denied.
Workaround: Reinstall or update the firmware on the vision system/sensor and then retry the Web HMI connection. |
6.1.0 |
| 48478 | If an In‑Sight vision system that runs firmware 5.6.0 or later has a job with many instances of the ReadIDMax function, the job might require more memory than is available on the vision system. Any instances of the ReadIDMax function that exceed the available memory returns #ERR. For example, if an In‑Sight 8405 vision system job contains more than 100 instances of the ReadIDMax function, you might encounter this problem. | 6.1.0 |
| 45581 | For In‑Sight 7000 Gen2 series and 9000 series vision systems configured for CIP‑Sync/PTP, 1588 synchronization accuracy through a transparent clock‑switch might increase to more than 10µs offset from master. | 6.1.0 |
| 35828 | If an industrial Ethernet communication protocol triggers the vision system, the JobPass signal is sent only if the job contains a WriteResultsBuffer function. This issue does not occur with EasyBuilder applications once the Communication application step has been configured. | 6.1.0 |
| 32479 |
If you update the In‑Sight vision system firmware while it is connected to a POWERLINK network, it results in a code 13710, with the vision system needing to be power cycled and the files restored (the firmware will be successfully updated, however).
Workaround: Before you update the vision system firmware, complete the following steps:
|
4.10.5 PR1 |