8400, 8401 & 8402 Vision System Specifications

Specifications 8400 8400C 8401 8401C 8402 8402C
Minimum Firmware Requirement In-Sight version 5.2.0 In-Sight version 5.5.0 In-Sight version 5.2.0 In-Sight version 5.5.0 In-Sight version 5.2.0 In-Sight version 5.5.0
Job/Program Memory 512MB non-volatile flash memory; unlimited storage via remote network device.
Image Processing Memory 512MB SDRAM
Sensor Type 1/1.8 inch CMOS, global shutter
Sensor Properties 3.6mm diagonal, 4.5 x 4.5μm sq. pixels 7.38mm diagonal, 4.5 x 4.5μm sq. pixels 9mm diagonal, 4.5 x 4.5µm sq. pixels
Maximum Resolution (pixels)1You can configure the number of image sensor rows and set them in the In-Sight Explorer software. If you decrease the number of rows, it increases the frames per second acquired by the vision system. Refer to the AcquireImage topic in the In-Sight® Explorer Help file for more information. 640 x 480 1280 x 1024 1600 x 1200
Electronic Shutter Speed 14µs to 520ms 17.4µs to 750ms 20µs to 940ms
Acquisition Rapid reset, progressive scan, full-frame integration.
Bit Depth 256 grey levels (8 bits/pixel) 24-bit color 256 grey levels (8 bits/pixel) 24-bit color 256 grey levels (8 bits/pixel) 24-bit color
Frames Per Second (FPS)2Maximum frames per second are job-dependent, based on the minimum exposure for a full image frame capture using the dedicated acquisition trigger, and assumes there is no user interface connection to the vision system. 217 FPS 135 FPS 76 FPS 45 FPS 53 FPS 33 FPS
Lens Type C-Mount
Trigger 1 opto-isolated, acquisition trigger input. Remote software commands via Ethernet. (RS-232C available when using the optional CIO-MICRO I/O module.)
Discrete Inputs None. (Eight additional general-purpose inputs available when using the optional CIO-MICRO I/O module.)
Discrete Outputs 2 opto-isolated, NPN/PNP high-speed output lines. (Eight additional general-purpose outputs available when using the optional CIO-MICRO I/O module.)
Status LEDs Network, 2 user-configurable.
Network Communication 1 Ethernet port, 10/100/1000 BaseT with auto MDIX. IEEE 802.3af or 802.3at TCP/IP Protocol. Supports DHCP (factory default), static and link-local IP address configuration.
Serial Communication None. (RS-232C: 4800 to 115,200 baud rates when connected to the optional CIO-MICRO I/O module.)
Power Class 2 Power over Ethernet (PoE) device.
Note: The In-Sight 8100, 8200 and 8400 series vision system must be connected to a Class 0, 2, 3 or 4 PoE power source, rated for at least 6.49 Watts.
Power Type PoE Type A and Type B.
Power Consumption 6.49 W maximum per Class 2 PoE.
Current Per Class 2 PoE requirements.
Voltage 48VDC nominal, applied from a Class 2 PoE source, which is typically powered from some other voltage.
Material Die-cast zinc housing.
Finish Painted.
Mounting Four M3 threaded mounting holes (1/4-20 and M6 mounting holes also available on accessory BKT‑IS8K‑01 mounting bracket).
Dimensions 31.0mm (1.22in) x 31.2mm (1.23in) x 75.1mm (2.96in).
Weight Vision system with no accessories attached: 132.2 g (4.66 oz.)
Case Temperature3To verify case temperature, use the EV GetSystemConfig(“Internal.Temperature”) Extended Native Mode command or GetSystemConfig(“Internal.Temperature”) spreadsheet function. When issued, it returns the vision system's internal temperature in degrees Celsius, which is ±5 degrees above the vision system case temperature. Refer to the In-Sight® Explorer Help file for more information.Additional cooling measures are required if the case temperature cannot be kept below 50°C. Examples of such measures include: mounting the vision system to a heat sink using the M3 mounting screws, reducing the ambient temperature and ensuring there is air flow over the vision system. 0°C to 50°C (32°F to 122°F)
Storage Temperature -20°C to 80°C (-4°F to 176°F)
Humidity < 80% non-condensing
Protection IP40 with cables and lens attached.
Shock (Shipping and Storage) IEC 60068-2-27: 18 shocks (3 shocks in each polarity in each (X, Y, Z) axis) 80 Gs (800m/s2 at 11ms, half-sinusoidal)
Vibration (Shipping and Storage) IEC 60068-2-6: vibration test in each of the three main axis for 2 hours @ 10 Gs (10 to 500 Hz at 100m/s2 / 15mm)
Regulations/Conformity CE, FCC, KCC, TÜV SÜD NRTL, EU RoHS, China RoHS