N Point Calibration Tool - Settings Tab
Defines the calibration file name (default name is Default).
Displays the full file name of the calibration file which appears in the Set Up Image step when the Calibration Type is configured to Import. The file must be exported before appearing in the Set Up Image step.
Exports the calibration file to the In-Sight vision system's local file system.
Defines whether or not the calibration file should be automatically exported on the first trigger after the job file is loaded or an image is acquired. When enabled (checked), the tool will automatically export its calibration file on the first trigger after the job file is loaded or an image is acquired (by default this setting is disabled/unchecked).
Note: If Auto Export is enabled, the job file containing the calibration data must first be saved before the calibration file will be exported. If after saving the job file the calibration file does not appear in the In-Sight Files pane, click on another In-Sight vision system or emulator and then return and select the desired vision system. The file should now appear.