In-Sight® Explorer 5.7.2 Release Notes

© Copyright 1999-2019 Cognex Corporation. All rights reserved.

Revision: 5.7.2.8, 06/11/2019

Overview

This document describes the In-Sight Explorer software, including the following topics:

Note: Visit the In-Sight Online Support Center to download the latest release notes and documentation, including localized editions. To access the updated documentation from the In-Sight Explorer user interface and Microsoft® Windows® Start menu, complete the following steps:

  1. Log on to the PC with administrative privileges.
  2. Copy the downloaded documentation to the appropriate location in the installation directory. The default location is: C:\Program Files (x86)\Cognex\In-Sight\In-Sight Explorer 5.x.x\Documentation.

System Requirements

This section describes system requirements for In-Sight Explorer software.

PC Hardware Minimum Requirements

The following minimum hardware requirements are for PCs that are connected to a single low-resolution In-Sight vision system running at a slow production speed:

PC Hardware Recommended Requirements

The following recommended hardware requirements are for PCs that are simultaneously connected to up to four In-Sight vision systems:

Operating System Requirements

In-Sight software has been tested on the following operating systems:

Although you can install and run In-Sight Explorer on other Windows operating systems, PCs that do not meet the preceding requirements are not officially supported.

Supported Languages

Firmware Version Support

In-Sight 5.7.2 software contains three firmware versions:

In-Sight vision systems that have older firmware versions might work properly. However, some features are unsupported with older firmware versions and are not fully tested. For optimal performance, update vision systems that run older firmware to the most recent, supported firmware versions. For a list of models and supported firmware versions, see the Firmware Versions topic in the In-Sight® Explorer Help file.

In-Sight Firmware 5.7.2

In-Sight Firmware 5.7.1

In-Sight Firmware 4.10.5 PR1

Microsoft .NET Framework 4.5

In-Sight software requires Microsoft .NET Framework 4.5. If the In-Sight software installer fails to detect Microsoft .NET Framework 4.5, it attempts to download and install it.

Note: If you attempt to install In‑Sight Explorer on a system with Microsoft .NET Framework 3.5 disabled while Windows updates are being installed, you may receive the following error message: Error installing Microsoft .NET Framework; Error code 0x800f081f. If this occurs, wait for the Windows updates to complete, reboot if necessary, and then install In‑Sight Explorer.

Changes & Fixes

Note:

Issue# Change/Fix
IS‑459 The performance of loading complex EasyBuilder jobs to the In-Sight vision system and/or sensor has been improved.
IS‑827 An unhandled exception error is no longer displayed when launching the Firmware Update dialog.
IS‑758 The PC filmstrip no longer slows down during image playback when connected to the In-Sight emulator.

Known Issues

Note: The release notes include issue numbers (where applicable) to better track known issues reported by Cognex Technical Support.
Issue# Issue Affected Firmware Version
IS-856

At times, saving a file to a sub-directory in an FTP server's root directory using the WriteImageFTP, WriteFTP or WriteImageSFTP function can result in the file being saved to the FTP server's root directory.

Workaround: Save files to the FTP server's root directory.

5.7.2, 5.7.1 & 4.10.5 PR1
IS-334

When you try to connect your vision system/sensor to the Web HMI for the first time, you may receive an error message: Permission error appears and connection is denied.

Workaround: Before you connect your vision system/sensor to the Web HMI, reinstall or update the vision system/sensor firmware on the system.

5.7.2 & 5.7.1
48478 If an In-Sight vision system that has a job with many instances of the ReadIDMax function, the job might require more memory than is available on the vision system. Any instances of the ReadIDMax function that exceed the available memory returns #ERR. For example, if an In-Sight 8405 vision system job contains more than 100 instances of the ReadIDMax function, you might encounter this problem. 5.7.2 & 5.7.1
45581 For In-Sight 7600/7800 series and 9902L vision systems configured for CIP-Sync/PTP, 1588 synchronization accuracy through a transparent clock-switch might increase to more than 10µs offset from master. 5.7.2 & 5.7.1
35828 If an industrial Ethernet communication protocol triggers the vision system, the JobPass signal is sent only if the job contains a WriteResultsBuffer function. This issue does not occur with EasyBuilder applications. 5.7.2 & 5.7.1
32479

If you update the In-Sight vision system firmware while it is connected to a POWERLINK network, it results in a code 13710, with the vision system needing to be power cycled and the files restored (the firmware will be successfully updated, however).

Workaround: Before you update the vision system firmware, complete the following steps:

  1. Remove the vision system from the POWERLINK network, and connect the vision system to a network port on the same subnet as the computer that runs In-Sight Explorer.
  2. Power cycle the vision system.
  3. Update the firmware while the vision system in Ethernet mode.
  4. Place the vision system back onto the POWERLINK network.
  5. Power cycle the vision system.
4.10.5 PR1