© Copyright 1999-2019 Cognex Corporation. All rights reserved.
Revision: 5.7.2.4, 05/07/2019
This document describes the In-Sight Display Control for Microsoft® Windows®, including the following topics:
The In-Sight Display Control (CvsInSightDisplay) forms the heart of the Job View window in In-Sight Explorer and provides a display of images, graphics and spreadsheet data when connected to an In-Sight vision system. This control is packaged as both a .NET control that can be inserted into a Microsoft Visual Studio C# .NET or VB.NET Windows Forms application and an ActiveX component that can be integrated into Visual Basic 6.0 or HMI/SCADA environments.
Note:
Visit the In-Sight Online Support Center to download the latest release notes and documentation, including localized versions.
This section describes system requirements for the In-Sight Display Control software.
The following minimum hardware requirements are for PCs that are connected to a single low-resolution In-Sight vision system running at a slow production speed:
The following recommended hardware requirements are for PCs that are simultaneously connected to up to four In-Sight vision systems:
In-Sight software has been tested on the following operating systems:
Although In-Sight Display Control may function on other operating systems, systems not meeting the preceding requirements have not been tested and are not supported.
In-Sight 5.7.2 software contains three firmware versions:
In-Sight vision systems that have older firmware versions might work properly. However, some features are unsupported with older firmware versions and are not fully tested. For optimal performance, update vision systems that run older firmware to the most recent, supported firmware versions. For a list of models and supported firmware versions, see the Firmware Versions topic in the In-Sight® Explorer Help file.
In-Sight software requires Microsoft .NET Framework 4.5. If the In-Sight software installer fails to detect Microsoft .NET Framework 4.5, it attempts to download and install it.
The In-Sight Display Control is installed with the In-Sight Software and In-Sight SDK installers, and you must be logged on as a user with full administrative privileges to install the software.
In-Sight Display Control Sample Projects are installed to the following folder: C:\Users\Public\Documents\Cognex\In-Sight\In-Sight Sample Projects 5.x.x. A shortcut on the Microsoft Windows Start menu is available to open this location.
Refer to the In-Sight Display Control help file for a complete list of enhancements and other API changes in this release of the In-Sight Display Control.
| Issue# | Issue |
|---|---|
| 5771 |
If you have multiple versions of In-Sight Software installed, uninstalling one version may result in the following error message when attempting to use the Cognex In-Sight Display Control (CvsInSightDisplay) in a VB6, COM or ActiveX environment: Component 'CvsInSightDisplay.ocx' or one of its dependencies not correctly registered: a file is missing or invalid. Workaround: To correct the issue, open the Windows Control Panel, select the desired In-Sight Software installation and perform a Repair. Note: Only one version of the In-Sight Display Control can be registered for COM/ActiveX on your system at a time, and this is always the latest version installed. Although applications compiled using an older version of the In-Sight Display Control may seem to function with this version installed, their compatibility with this version is not guaranteed.
|
| 5319 |
When a PairDistance function is added to an Abs formula, as in either of the following examples, "Abs(B2)+PairDistance(C2,0,1)" or "PairDistance(C2,0,1)+Abs(B2)", the expression may cause the Property Sheet to open incorrectly. Workaround: The PairDistance function should be placed in its own cell and referenced by the other expression. |
| 5230 | If you add an OPC Tag from an In-Sight Display Control, the corresponding OPC Tag inside the In-Sight OPC Server must use the exact same upper and lower case characters. If the two names do not match exactly, a Configuration Error will result in the OPC Server. |
| 5093 | The Open and Save File dialogs (such as CTRL+O), when invoked from the In-Sight Display Control in a custom .NET or ActiveX environment, differ in behavior from the Open/Save File dialogs launched from In-Sight Explorer. Under the list of "In-Sight Sensors," In-Sight Explorer will list all In-Sight vision systems on the local subnet and any Explorer Host Table entries. When launched from an In-Sight Display control in a .NET or ActiveX environment, however, these same dialogs will show the list of all systems on the local subnet and In-Sight Host Table entries stored on the vision system to which the display is connected. |