Release 5.6.0 PR1 is a patch release for In-Sight 5.6.0 firmware. This release provides fixes to known issues and does not include any new functionality.
Note: Visit the In-Sight Online Support Center to download the latest release notes and documentation, including localized editions. To access the updated documentation from the In-Sight Explorer user interface and Windows® Start menu, complete the following steps:
This section describes system requirements for the In-Sight Explorer software.
In-Sight software has been tested on the following operating systems:
Although you can install and run In-Sight Explorer on other Windows operating systems, PCs that do not meet the preceding requirements are not officially supported.
Notes:
| CR# | Change/Fix | Applicable Firmware Version |
|---|---|---|
| 79073 | For In-Sight 2000 series vision sensors with the HMI Server enabled, stability issues no longer occur when the sensor is connected to the Web HMI through a high-traffic network. Previously, the vision sensor could become unresponsive and disconnect from the network, requiring a power-cycle. | 5.6.0 PR1 |
| 79668 | When an In-Sight 2000 series color vision sensor is connected to a Web HMI and acquiring images as fast as possible, the vision sensor trigger rate is no longer affected. Previously, the trigger rate could drop significantly. | 5.6.0 PR1 |
| 81197 |
If the Sensor Filmstrip Queue Size is configured to save the maximum number of images to the vision system, the vision system is placed Online and an image is selected in the filmstrip queue, the spreadsheet cell content now remains intact. Previously, the contents of the spreadsheet cells might have been erased. |
5.6.0 PR1 |
| CR# | Issue | Affected Firmware Version |
|---|---|---|
| 79652 | For In-Sight 2000 series vision sensors running firmware version 5.6.0, the Maximum View Connections (In-Sight Explorer, VisionView or Web HMI) is limited to 2. | 5.6.0 PR1 |
| 79345 | When Web HMI is in use, do not run PROFINET cyclic I/O faster than 8ms. | 5.6.0 PR1 |
| 78064 |
If an In-Sight 8000 series vision system or In-Sight 2000 series vision sensor is running firmware version 5.6.0 and downgraded to 5.5.x firmware or earlier, non-English files may be deleted from the vision system/sensor. Even if the files are manually backed up using the Backup dialog prior to the process, non-English files may not be restored after the downgrade. Workarounds: To restore non-English files, do one of the following workarounds:
|
5.6.0 PR1 and earlier |
| 48636 | If an In-Sight 7600/7800 series vision system that shipped with 5.5.0 or later firmware is then downgraded to 5.4.1 firmware or earlier, it may take approximately four minutes for the vision system to reboot when power-cycled. | 5.6.0 PR1 and earlier |
| 48478 | If an In-Sight vision system running firmware 5.6.0 has a job with many instances of the ReadIDMax function, the job may require more memory than is available on the vision system and any instances of the ReadIDMax function that exceed the available memory will return #ERR. For example, if an In-Sight 8405 vision system job contains more than 100 instances of the ReadIDMax function, this problem may be encountered. | 5.6.0 PR1 |
| 45581 | For In-Sight 7600/7800 series vision systems configured for CIP-Sync/PTP, 1588 synchronization accuracy through a transparent clock-switch may increase to greater than 10µs offset from master. | 5.6.0 PR1 |
| 43186 | While configuring a Serial Text, Serial Native, TCP/IP or UDP device in the Communication application step on an In-Sight 2000 series vision sensor, the FormatString dialog will show #ERR in the Output String box. To see the Output String, you must click OK to close the dialog, and then the Output String is displayed correctly in the Format Output String tab. | 5.6.0 PR1 |
| 42550 | In-Sight Track & Trace job files are not supported on In-Sight models running 5.1.0 and later firmware versions. | 5.6.0 PR1 |
| 35828 | If the vision system is triggered via an industrial Ethernet communication protocol, the JobPass signal is only sent if the job contains a WriteResultsBuffer function. This is not an issue for EasyBuilder applications. | 5.6.0 PR1 |
| 32479 |
Updating the firmware of an In-Sight vision system while connected to a POWERLINK network will result in a code 13710, with the vision system needing to be power cycled and the files restored (the firmware will be successfully updated, however). Workaround: Before updating the vision system's firmware, follow these steps:
|
4.10.5 |