The Trigger tab of the Acquisition panel allows you to configure the following trigger settings:
| Parameter | Description |
|---|---|
| Trigger Type |
Defines the type of trigger signal that begins an image acquisition.
|
| Trigger Source |
Specifies the trigger source for the acquisition:
|
| Motion Input |
Defines the acquisition driving logic for every profile:
Note: This setting affects field correction. Therefore, make sure to configure it before performing field correction on the device in the Correction Settings.
|
| Encoder Type |
Specifies whether the encoder signal used for acquisition is single or dual-channel:
Note: This setting affects field correction. Therefore, make sure to configure it before performing field correction on the device in the Correction Settings.
|
| Encoder Counter |
Indicates the current encoder position so that you can check if the encoder is wired correctly and working properly. The Encoder Counter always has a positive value that you can reset with the Reset button. Note: The Encoder Counter works only if Motion Input is set to Encoder.
|
| Time Trigger Delay (ms) |
Specifies a time delay (in milliseconds) between the trigger signal and the start of the acquisition. The value range is 0 – 10,000, and the default value is 0, which means no time delay between the trigger signal and the acquisition. Note: This setting is enabled only if Motion Input is set to Time.
|
|
Distance Trigger Delay (mm) |
Specifies the amount of distance (in mm) between the trigger signal and the start of the point cloud acquisition. The value range is 0 – 10,000, and the default value is 0, which means no distance-based delay between the trigger signal and the acquisition. Note:
|
| Acquisition Direction |
Specifies in which motion direction you want to acquire. This setting is independent of the Positive Encoder (+) setting.
Tip: By default, you can trigger acquisitions only in one direction. If you want to trigger acquisitions in both directions (that is, both toward and away from the vision system), change the Acquisition Direction setting after performing the first acquisition.
|
| Acquisition Timeout |
Specifies the amount of time (in milliseconds) before an acquisition times out after a trigger.
|