In-Sight 3800 Series Vision System

Specification In-Sight 3800
Lens Type

C-Mount, Cognex High Speed Liquid Lens Autofocus, or Cognex manual focus lens (used with Multi-Torch Illumination accessory).

Trigger 1 opto-isolated, acquisition trigger input.
Discrete Inputs

1 opto-isolated, acquisition trigger input.

Up to 3 general-purpose inputs when connected to the Breakout cable.

Discrete Outputs

Up to 4 high-speed outputs when connected to the Breakout cable.

Status LEDs Pass/Fail LED and Indicator Ring, Network LED, and Error LED.
Memory 4 GB
Image Processing Memory 512 MB SDRAM
Job / Program Storage 7.2 GB non-volatile flash memory; unlimited storage via remote network device.
Network Communication

2 Ethernet ports, 10/100/1000 BaseT with auto MDIX. IEEE 802.3 TCP/IP Protocol.

Supports DHCP, static, and link-local IP address configuration. One port supports TSN networks.

Power Consumption

24 V DC ± 10%, 2.0 A maximum.

Power Output 24 V DC at 1.0 A maximum to external light.
Material Die-cast and extruded aluminum housing.
Finish Painted.
Mounting

Four M3 threaded mounting holes. See Mounting Brackets for supported mounts.

Pattern: 38.5 × 58.5 mm (1.52 × 2.60 in)

Weight

In-Sight 3800 with no accessories attached: 570 g (20.10 oz).

  • with 45 mm plastic C-Mount cover (COV-380-CMNT-45): 625 g (22.0 oz.) - no lens included.

  • with 60 mm plastic C-Mount cover (COV-380-CMNT-60): 635 g (22.4 oz.) - no lens included.

  • with 75 mm plastic C-Mount cover (COV-380-CMNT-75): 650 g (22.9 oz.) - no lens included.

  • with Multi-Torch Illumination, High Speed Liquid Lens (16 mm), and standard front cover: 840 g (29.6 oz.).

  • with Multi-Torch Illumination, High Speed Liquid Lens (16 mm), and dome attachment: 970 g (34.2 oz.).

Case Temperature 0° C to 40° C (32° F to 122° F)
Storage Temperature -20° C to 80° C (-4° F to 176° F)
Humidity < 95% non-condensing
Protection

IP67 with all cables properly attached (or the provided connector plug installed) the IP67-rated cover or Multi Torch attachment properly installed.

Shock (Shipping and Storage)

IEC 60068-2-27: 18 shocks (3 shocks in each polarity in each [X, Y, Z] axis) 80 Gs (800 m/s2 at 11 ms, half-sinusoidal) with cables or cable plugs and a 150 gram or lighter lens attached.

Vibration (Shipping and Storage) IEC 60068-2-6: vibration test in each of the three main axis for 2 hours at 10 Gs (10 to 500 Hz at 100 m/s2 / 15 mm) with cables or cable plugs and a 150 gram or lighter lens attached.
Regulations/Conformity CE, FCC, KCC, TÜV SÜD NRTL, EU RoHS, China RoHS