EtherNet/IP Output Assembly - Instance 22
Note: For detailed descriptions of the signals, see Industrial Communications Signals.
| Instance | Byte | Bit 7 | Bit 6 | Bit 5 | Bit 4 | Bit 3 | Bit 2 | Bit 1 | Bit 0 |
|---|---|---|---|---|---|---|---|---|---|
| 22 |
0 |
Set Offline |
Reserved |
Execute Command |
Inspection ResultsAck |
Buffer Results Enable |
Trigger
|
Trigger Enable | |
|
1 |
Reserved |
||||||||
|
2 |
Reserved |
Clear Exposure Complete |
Clear Error | Reserved | Set User Data | ||||
|
3 |
External Event7 |
External Event6 |
External Event5 |
External Event4 |
External Event3 |
External Event2 |
External Event1 |
External Event0 |
|
|
4 .. 5 |
Command ID |
||||||||
|
6 .. 7 |
Reserved |
||||||||
|
8 .. 495 |
User Data 0 - 487 |
||||||||