HPIT.OUTPUT-CONFIG-CUSTOM-INDICATOR

Enable/Disable the use of the right HPIT indicator functionality with a given time length. As a default, none of the outputs is enabled.

Actions

SET/GET Property

Arguments

Name Type Range Meaning
OUTPUT_NUMBER int [0-27] 0 = Good read
1 = Bad read
2 = Reader programming
3 = Reader programming failure
4 = Reader programming
5 = Offline buffer low
6 = Offline buffer full
7 = Out of range
8 = Validation failure
9 = Consecutive bad read
10 = Image buffer overrun
11 = Trigger overrun
12 = Symbology learn success
13 = Symbology learn failure
14 = Train focus started
15 = Train focus success
16 = Train focus failure
17 = Optimize brightness started
18 = Optimize brightness success (Grade A)
19 = Optimize brightness success (Grade B)
20 = Optimize brightness success (Grade C)
21 = Optimize brightness failure
22 = Trigger detected
23 = Learn trigger detected
24 = Height sensor error
25 = Devlog error
26 = User event 1
27 = User event 2
state bool [ON|OFF] enable/disable
TIME_LENGTH_US int [0 - 20000] microseconds

Platforms

DM370, DM470.

Notes